PRODUCT

We are always looking for better treatment options for patients by working with health care professionals and investing in research and development.

Product

MINDD STIM

MINDD STIM

Wireless Non-invasive Brain Stimulation System
  • The first
    in Korea

  • Fine electric
    stimulation

  • Home
    care

  • Hospital
    centric

MINDD is a digital health care device that aims hospital and home connected treatment. Under the directions of doctor, patients use the device and treat themselves at home conveniently. Hospitals can also check treatment records on the machine, allowing them to manage patient’s treatment.

Features

  • Stimulation

    MINDD helps to activate neuronal communication in the cerebral cortex using micro electrical stimulation.

    • 2 electrodes (1 anode)
    • tDCS
    • Flexible electrode placement with the 10-20 system
    • Independent current control
    • Prescription control for at-home and in-clinic use
    • Configurable sham and real mode
  • Safety

    Electrical stimulation is securely controlled by MINDD software. 

    • Maximum current limited by hardware and software
    • Programmable stimulation duration
    • Cap for electrode placement for montages
    • Impedance monitoring for automatic start/stop
    • Automatic stimulation abort if abnormal state is detected
  • Convenient

    Convenient and safe domiciliary treatment is possible wit MINDD.

    • Prescription by station and stimulation anywhere (e.g., clinic, home, office, etc.)
    • Easy setup ( ≤ 5min)
    • User-friendly configuration MINDD Station
    • Compliance Management
    • Device Management
    • Patient Management

Product Contents

  • 01

    Station

    모듈에 처방을 내릴 수 있으며 처방 및 치료 내역을 확인 할 수 있는 소프트웨어가 탑재 된 HW 기기

  • 02

    Module Packages

    처방된 내역에 맞게 환자에 자극을 줄 수 있는 장치

  • 03

    2 Patch package

    피부에 부착되는 스펀지 타입의 패치와 그 패치를 고정하기 위한 패치 서포터

  • 04

    Charger

    모듈을 충전 할 수 있는 충전 슬롯

  • 05

    Charge Cable

    스테이션의 충전과 작동을 위해 필요한 전원 어댑터.

Technical Spec

마인드스캔의 EEG측정 스펙 기본구성내용 입니다.

Technical Spec / MINDD 1.1.x Spec 
Technical Spec MINDD 1.1.x
STIMULATION Number of channels 1
Electrode management MINDD band
Types of Stimulation tDCS with sham
tACS frequency range N.A. 
Current up to 2mA
Individual and independenct current configuration N.A. 
Current accuracy < 1%
Current resolution 0.1mA 
Configurable Ramp­up and Ramp­down times from 1 sec to 120 sec
Voltage up to 15V
Automatic tDCS session control (auto­start &  auto­resume)  yes
SAFETY Current at electrode limited to < 2 mA
Maximum total current injected by all electrodes at a  time limited to <  2 mA
Configurable stimulation duration ≤ 1h
Impedance check always and automatic turnoff when no use
Stimulation Abort Method yes, unwearing the device, by software   
External
interaction
Additional ExG Channels (EOG, EMG, ECG) Not supported
External Trigger Not supported
Support of Simultaneous recording Not supported
Output Private API through Serial Port 
Output through Internet Supported by software library
Accelerometer (Axis) 3
Gyrometer (Axis) N.A.
Magnetometer (Axis)  N.A.
Other
technical
spec
On­board storage 8M Byte Internal flash
≤ 6 10 min sessions
data reading through USB type C
Sampling rate (SPS) for internal log 0.2 (one sample every 5 sec)
USB rechargeable system using Li­Ion battery O
Operating time: eep mode : 40h / Active : 2h / BLE only : 59d
Dimensions 60 x 92 x 17.15 mm
Weight 52  
Simulation
Technical Spec MINDD 1.1.x
Number of channels 1
Electrode management MINDD band
Types of Stimulation tDCS with sham
tACS frequency range N.A.
Current  up to 2mA
Individual and
independenct
current configuration
N.A.
Current accuracy < 1%
Current resolution 0.1mA 
Configurable Ramp­up
and Ramp­down times
from 1 sec to 120 sec
Voltage up to 15V
Automatic tDCS
session control
(auto­start & auto­resume) 
yes
Safety
Technical Spec MINDD 1.1.x
Current at electrode limited to < 2 mA 
Maximum total current
injected by all electrodes
at a time
limited to <  2 mA
Configurable
stimulation duration
≤ 1h
Impedance check always and automatic
turnoff when no use
Stimulation
Abort Method  
yes, unwearing the
device, by software   
External interaction
Technical Spec MINDD 1.1.x
Additional ExG Channels
(EOG, EMG, ECG)
Not supported 
External Trigger Not supported 
Support of Simultaneous
recording
Not supported
Output Private API through
Serial Port 
Output through Internet Supported by
software library
Accelerometer (Axis) 3
Gyrometer (Axis) N.A. 
Magnetometer (Axis)  N.A. 
Other technical spec
Technical Spec MINDD 1.1.x
On­board storage 8M Byte Internal flash
≤ 6 10 min sessions
data reading through
USB type C
Communication Bluetooth Low
Energy and USB
Sampling rate
(SPS) for internal log
0.2 (one sample
every 5 sec)
USB rechargeable
system using
Li­Ion battery
O
Operating time: eep mode : 40h /
Active : 2h /
BLE only : 59d
Dimensions 60 x 92 x 17.15 mm
Weight 52

MINDD STIM Station / Web Dashboard Spec

Feature Basic Standard Professional
MINDD Stim
Station
기기설정 
(Customizable 
Prescription)
MINDD tDCS O O O
Prescription O O O
stimulation parameter configuration (see technical spec) O O O
At­home and in­clinic mode O O O
Flexible schedule configuration for  stimulation  O O O
회수 관리
(Stimulation
Log  Retrieval)
Log Retrieval O O O
Log management O O O
사용자 관리
(Patient
Management) 
User (Subject) management O O O
add and edit subjects O O O
모듈 관리
(Module
Management) 
Module status management O O O
Per­device real and sham configuration X O O
기타 (Other
Technical
Features) 
Account management & access control X* O O
Offline function X O O
Advanced
Features
Multi­sites Stimulation X O O
Private SDK for custom applications X X TBD
tCS (tDCS, tRNS, tPCS, and tACS)  support X X O
MINDD
Dashboard
MINDD Stim
Station
Integration
Station 기본 내용 Web dashboard 표현 O O O
MINDD Stim Station
Features Basic Standard Professional
기기설정 
(Customizable 
Prescription)
MINDD tDCS O O O
Prescription O O O
stimulation parameter
configuration
(see technical spec)
O O O
At­home and
in­clinic mode
O O O
Flexible schedule
configuration for 
stimulation 
O O O
회수 관리
(Stimulation
Log  Retrieval)
Log Retrieval O O O
Log management  O O O
사용자 관리
(Patient
Management) 
User (Subject)
management
O O O
add and edit subjects O O O
모듈 관리
(Module
Management) 
Module status
management
O O O
Per­device real and 
sham configuration
X O O
기타 (Other
Technical
Features) 
Account management 
& access control
X* O O
Offline function X O O
Advanced
Features
Multi­sites Stimulation X O O
Private SDK for custom
applications
X X TBD
tCS (tDCS, tRNS, tPCS,  and tACS) support X X O
MINDD Stim Station
Features Basic Standard Professional
MINDD Stim
Station
Integration
Station 기본 내용 
Web dashboard 표현 
O O O

FAQ

Q
Can an individual buy this?
A.No
Q
What are the side effects?
A.Each user may have different feeling.
TOP